The Columbia Series 5812 In-Line Charge Converters are specifically designed to convert the charge signals from a high impedance piezoelectric sensor into a voltage signal output with low output impedance, thereby eliminating the need for costly charge amplifiers in many applications. This device can be used with all Columbia non-integrated piezoelectric accelerometers and pressure sensors.
The advantage of this device is that it contains three active signal channels powered from a common external standard DC power supply. This makes it the perfect signal?conditioning match for any high impedance triaxial piezoelectric sensor. The converter is available in three factory setting of 0.1, 1.0 and 10.0 mV/pcmb. Sensor inputs utilize a #10?32 coaxial connector with the signal output presented on BNC connectors. Power is applied via the two binding posts.
Consult the factory for customizes versions of these sensors.
Output Impedance | <50Ω for Models 5812-01 and 5812-1, <200Ω for Model 5812-10 |
---|---|
Input Resistance | 10MΩ Min |
Output Load Capacitance | 100nF Max. for No Effect Gain Accuracy Below 10kHz |
Input Source Capacitance | 5000 pF Max. |
Output DC Bias | 9-11 Volts Typical |
Output Voltage Swing | 10 Volts Min. @ +22VDC Power, 15 Volts Min. Above +25VDC Power |