The Columbia Model SA-100MR offers the superior performance of force balance technology with the flexibility of multiple operating ranges for DC and low frequency measurements. The accelerometer is self-contained and provides a high level, low impedance output. No signal conditioning is required in most applications.
The full range for Model SA-100MR is specified when the accelerometer is ordered. The range may then be adjusted from 0.05 to 1 times the full range by means of an external resistor. The selected range always corresponds to an output of ±7.5 volts. The noise floor remains constant and does not increase as the scale factor is increased, thereby achieving the optimum signal-to-noise ratio for any range selected.
Notes:
Exports of accelerometers from the United States are subject to the licensing requirements of the Export Administration Regulations (EAR) and/or the International Traffic in Arms Regulations (ITAR).
Output Impedance | 100 Ohms Typical |
---|---|
Ranges Available | +1G, +5G, +10G, +50G |
Output Voltage | +7.5 Volts Adjustable From F.R. to 10% of F.R. |
Excitation | +12 VDC to +15 VDC 8 mA Standby, 20 mA @ F.R. |
Sensitive Axis Alignment | Better than 0.25 Deg |
Scale Factor Tolerance | +1% |
Scale Factor Temp Coefficient | +0.02% / Deg C |
Zero Bias | +0.15% F.R. |
Null Temp Sensitivity | 0.00015% F.R. / Deg C |