P 200 1

P 200 1

  • Fast Pressure Variations
  • Surges & Dynamic Blasts
  • Very Low & High Pressure
  • Wide Frequency Response
  • Small Size / Lightweight
  • Case Grounded or Electrically Isolated
Download Spec Sheet

The Columbia Series P200 High Intensity Acoustic Sensors (Microphones) are designed to measure a wide range of dynamic pressure variations, including high intensity sound pressure levels in applications requiring fast rise times and broad frequency response. The sensor is very sensitive allowing very low pressure measurements to 0.01 psi as well as high pressure transient measurements to 5,000 psi at temperatures up to +150 Degrees C.

The P200 Series has a flush diaphragm and incorporates an O-ring seal. The special case construction, although very small in size, provides the advantages of very high natural frequency and exceptional mechanical isolation along with extreme ruggedness. The Model P-200-2 provides additional electrical isolation for prevention of ground loops. Consult the factory for customized versions of this sensor.

Notes:
With Connector Mated or Protected, Unit is Hermetically Sealed.

Specifications

Charge Sensitivity 25 pC / psi
Pressure Range 0.01 To 5,000 psi
Pressure Overload 50%
Resonant Frequency 90KHz
Amplitude Linearity +/-2%
Capacitance 500 pF
Grounding Case Grounded
Frequency Response 2 To 18,000 Hz
Product Lines
Web Statistics