Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.

  • High Temperature, Reliability and Performance
  • Long Term Stability and Long Life
  • Light weight
  • Magnetic Shielding
  • Wide Temperature Range
  • Corrosion Resistant Materials
  • Low Mass

L.V.D.T. General Purpose - AC Operation

The S Series LVDT's are Columbia's general purpose line of LVDTs. They are designed to sense linear displacement over the ranges of +/-0.04" to +/-0.30" and translate this motion into a precisely proportional voltage for measurement and control.


Click here to view L.V.D.T. General Purpose - AC Operation
Model Frequency Range Temperature Range Linear Range inch Input Voltage Vrms Linearity Percent Full Range Size
S040-SxR 50Hz to 3KHZ -40 to +200 Deg. F 0.08 5 0.20% 7/8" Dia.
S040-SxRC 50Hz to 3KHZ -40 to +200 Deg. F 0.08 5 0.20% 7/8" Dia
S050-SxR 50Hz to 3KHZ -40 to +200 Deg. F 0.1 5 0.20% 7/8" Dia.
S050-SxRC 50Hz to 3KHZ -40 to +200 Deg. F 0.1 5 0.20% 7/8" Dia
S080-SxR 50Hz to 3KHZ -40 to +200 Deg. F 0.16 5 0.20% 7/8" Dia
S080-SxRC 50Hz to 3KHZ -40 to +200 Deg. F 0.16 5 0.20% 7/8" Dia.
S150-SxR 50Hz to 3KHZ -40 to +200 Deg. F 0.3 5 0.20% 7/8" Dia.
S150-SxRC 50Hz to 3KHZ -40 to +200 Deg. F 0.3 5 0.20% 7/8" Dia
S200-SxR 50Hz to 3KHZ -40 to +200 Deg. F 0.4 5 0.20% 7/8" Dia.
S200-SxRC 50Hz to 3KHZ -40 to +200 Deg. F 0.4 5 0.20% 7/8" Dia.
S300-SxR 50Hz to 3KHZ -40 to +200 Deg. F 0.6 5 0.20% 7/8" Dia
S300-SxRC 50Hz to 3KHZ -40 to +200 Deg. F 0.6 5 0.20% 7/8" Dia.

 

L.V.D.T. Miniature Size - A/C Operation

The M Series of LVDT's designed by Columbia Research Labs are ideal for use on small, high-speed mechanisms and in sensitive low-displacement applications. Linear motions over the ranges of +/-0.003" to +/-0.150" are translated into precisely proportional voltage for measurement and control.


Click here to view L.V.D.T. Miniature Size - A/C Operation
Model Frequency Range Temperature Range Linear Range inch Input Voltage Vrms Linearity Percent Full Range Size
M005-SxR 400Hz to 10KHz -65 to +275 Deg. F 0.01 4 0.25% 3/8" Dia.
M005-SxRC 400Hz to 10KHz -65 to +275 Deg. F 0.01 4 0.25% 3/8" Dia.
M010-SxR 400Hz to 10KHz -65 to +275 Deg. F 0.2 4 0.25% 3/8" Dia.
M010-SxRC 400Hz to 10KHz -65 to +275 Deg. F 0.2 4 0.25% 3/8" Dia.
M020-SxR 400Hz to 10KHz -65 to +275 Deg. F 0.4 4 0.25% 3/8" Dia.
M020-SxRC 400Hz to 10KHz -65 to +275 Deg. F 0.4 4 0.25% 3/8" Dia.
M050-SxR 400Hz to 10KHz -65 to +275 Deg. F 0.1 4 0.25% 3/8" Dia.
M050-SxRC 400Hz to 10KHz -65 to +275 Deg. F 0.1 4 0.25% 3/8" Dia.
M100-SxR 400Hz to 10KHz -65 to +275 Deg. F 0.2 4 0.25% 3/8" Dia.
M100-SxRC 400Hz to 10KHz -65 to +275 Deg. F 0.2 4 0.25% 3/8" Dia.
M150-SxR 400Hz to 10KHz -65 to +275 Deg. F 0.3 4 0.25% 3/8" Dia.
M150-SxRC 400Hz to 10KHz -65 to +275 Deg. F 0.3 4 0.25% 3/8" Dia.

 

L.V.D.T. High Stroke/Length Ratio - A/C Operation

The Columbia H Series LVDT's provides an exceptionally high stroke-to-length ratio while maintaining excellent performance. With a linear range of +/- 1.0" to +/- 3.0" the H Series has found extensive application in position sensing and displacement measurement on large valves and remotely operated industrial process controls.


Click here to view L.V.D.T. High Stroke/Length Ratio - A/C Operation
Model Frequency Range Temperature Range Linear Range inch Input Voltage Vrms Linearity Percent Full Range Size
H1000-SxR 60Hz to 5KHz -65 to +275 Deg. F 2 5 0.50% 5/8" Dia.
H1000-SxRC 60Hz to 5KHz -65 to +275 Deg. F 2 5 0.50% 5/8" Dia.
H2000-SxR 60Hz to 5KHz -65 to +275 Deg. F 4 5 0.50% 5/8" Dia.
H2000-SxRC 60Hz to 5KHz -65 to +275 Deg. F 4 5 0.50% 5/8" Dia.
H3000-SxR 60Hz to 5KHz -65 to +275 Deg. F 6 5 0.50% 5/8" Dia.
H3000-SxRC 60Hz to 5KHz -65 to +275 Deg. F 6 5 0.50% 5/8" Dia.

 

L.V.D.T. Displacement Transducers - DC Operation


The Columbia DDCP Series Transducers are completely self-contained displacement measurement systems that operate from a low voltage DC power supply or battery. They permit highly accurate readout and recording of an output signal directly without auxiliary signal conditioning electronics.

Click here to view L.V.D.T. Displacement Transducers - DC Operation
Model Temperature Range Linear Range Inch Input Voltage Vrms Linearity Percent Full Range Linear Range Inch Sensitivity mV 0001 inch Termination
DDCP-0100-020 -40 to 200 Deg. F 0.2 +28 VDC ±0.25% 0.2 50 30
DDCP-0100-02T -40 to 500 Deg. F 0.2 +28 VDC ±0.25% 0.2 50 30" Cable Lead
DDCP-0100-030 -40 to 200 Deg. F 0.2 +28 VDC ±0.25% 0.2 50 4- Pin Connector
DDCP-0100-03T -40 to 500 Deg. F 0.2 +28 VDC ±0.25% 0.2 50 4-Pin Connector
DDCP-0100-220 -40 to 200 Deg. F 0.2 +12 VDC ±0.25% 0.2 50 30" Cable Lead
DDCP-0100-22T -40 to 500 Deg. F 0.2 +12 VDC ±0.25% 0.2 50 30" Cable Lead
DDCP-0100-230 -40 to 200 Deg. F 0.2 +12 VDC ±0.25% 0.2 50 4-Pin Connector
DDCP-0100-23T -40 to 500 Deg. F 0.2 +12 VDC ±0.25% 0.2 50 4-Pin Connector
DDCP-0250-020 -40 to 200 Deg. F 0.5 +28 VDC ±0.5% 0.5 20 30
DDCP-0250-02T -40 to 500 Deg. F 0.5 +28 VDC ±0.5% 0.5 20 30
DDCP-0250-030 -40 to 200 Deg. F 0.5 +28 VDC ±0.5% 0.5 20 4 Pin Connector
DDCP-0250-03T -40 to 500 Deg. F 0.5 +28 VDC ±0.5% 0.5 20 4-Pin Connector
DDCP-0250-220 -40 to 200 Deg. F 0.5 +12 VDC ±0.5% 0.5 20 30" Cable Lead
DDCP-0250-22T -40 to 500 Deg. F 0.5 +12 VDC ±0.5% 0.5 20 30" Cable Lead
DDCP-0250-230 -40 to 200 Deg. F 0.5 +12 VDC ±0.5% 0.5 20 4 Pin Connector
DDCP-0250-23T -40 to 500 Deg. F 0.5 +12 VDC ±0.5% 0.5 20 4-Pin Connector
DDCP-0500-020 -40 to 200 Deg. F 1.0 +28 VDC ±0.5% 1 10 30
DDCP-0500-02T -40 to 500 Deg. F 1.0 +28 VDC ±0.5% 1 10 30" Cable Lead
DDCP-0500-030 -40 to 200 Deg. F 1.0 +28 VDC ±0.5% 1 10 4 Pin Connector
DDCP-0500-03T -40 to 500 Deg. F 1.0 +28 VDC ±0.5% 1 10 4-Pin Connector
DDCP-0500-220 -40 to 200 Deg. F 1.0 +12 VDC ±0.5% 1 10 30" Cable Lead
DDCP-0500-22T -40 to 500 Deg. F 1.0 +12 VDC ±0.5% 1 10 30" Cable Lead
DDCP-0500-230 -40 to 200 Deg. F 1.0 +12 VDC ±0.5% 1 10 4 Pin Connector
DDCP-0500-23T -40 to 500 Deg. F 1.0 +12 VDC ±0.5% 1 10 4-Pin Connector
DDCP-1000-020 -40 to 200 Deg. F 2.0 +28 VDC ±0.5% 2 5 30" Cable Lead
DDCP-1000-02T -40 to 500 Deg. F 2.0 +28 VDC ±0.5% 2 5 30
DDCP-1000-030 -40 to 200 Deg. F 2.0 +28 VDC ±0.5% 2 5 4 Pin Connector
DDCP-1000-03T -40 to 500 Deg. F 2.0 +28 VDC ±0.5% 2 5 4-Pin Connector
DDCP-1000-220 -40 to 200 Deg. F 2.0 +12 VDC ±0.5% 2 5 30" Cable Lead
DDCP-1000-22T -40 to 500 Deg. F 2.0 +12 VDC ±0.5% 2 5 30" Cable Lead
DDCP-1000-230 -40 to 200 Deg. F 2.0 +12 VDC ±0.5% 2 5 4 Pin Connector
DDCP-1000-23T -40 to 500 Deg. F 2.0 +12 VDC ±0.5% 2 5 4-Pin Connector

 

Linear Motion Tandem Transducer

The Columbia Model LMT-50 is a unitized rugged package consisting of tandem linear variable differential transformers (LVDT's) with probe assembly. The LMT-50 is designed so that the likelihood of a single failure affecting both output signals is extremely improbable. The model LMT-50 offers flight proven performance, even in then most severe environments.


Click here to view Linear Motion Tandem Transducer
Model Operating Range Sensitivity Excitation Details Temperature Range Accuracy
LMT-50 0.10: ±0.05 from electrical zero 6,000 volts/inch/volt ±5% 6.0 VRMS Nominal Dual Tandem LVDTs -55° C to +71° C ±0.0004

 

L.V.D.T. Controller

Columbia's single and dual channel microprocessor-based LVDT indicator and set-point controllers are designed for industrial and process control applications utilizing and Columbia H, M, or S series LVDT. IN addition to displaying real-time LVDT readings, these instruments display MIN, MAX and TIR values.

Click here to view L.V.D.T. Controllers
Model Sensitivity Output Temperature Range Linearity Percent Full Range Power Requirements
LD4310 1.8 or4.5 V rms 5VDC, 50mA per setpoint 0 to +55 °C < ±0.02% 100 to 250 VDC
LD4320 1.8 or4.5 V rms 5VDC, 50mA per setpoint 0 to +55 °C < ±0.02% 100 to 250 VDC